Edwards nXDS10iC Dry Chemistry and Vapor Pump Scroll Pump, A73602983
Edwards Vacuum nXDS10iC Dry Chemistry and Vapor Pump Scroll Pump 100 - 127 V, 200 - 240 V, 1ph 50/60 Hz A73602983
The nXDS version offer increased pumping speeds combined with lower ultimate pressures, lower power consumption and lower noise. Gast ballast allows for pumping of condensable vapours including water, solvents, dilute acids and bases. nXDS pumps give longer life between tip seal changes.
The nXDS-C pump is a modified version of the nXDS that is suitable for use on vapour handling processes, and may be used for some pumping applications involving corrosive substances. The nXDS-C variants have Chemraz® internal valves and stainless steel fittings for extra protection from the pumped media.
Features and Benefits
- Quiet Operation
- Intelligent and easy to use controls
- Hermetically sealed for a lubricant-free vacuum environment
- No oil to dispose of
- Long service interval
Applications
- General clean pumping applications
- Scanning Electron Microscopes - SEM
- Beam lines and high energy physics
- Backing turbo pumps
- Centrifuges, ultra- high speed
Nominal rotational speed | 1800 rpm |
Displacement | 12.7 m3h-1 / 7.5 ft3min-1 |
Peak pumping speed | 11.4 m3h-1 / 6.7 ft3min-1 |
Ultimate vacuum (total pressure) | 0.007 mbar / 0.005 Torr |
Minimum standby rotational speed | 1200 rpm |
Speed control resolution (percentage of full rotation speed) | 1% |
Pumping speed at minimum rotational speed | 7.5 |
Maximum continuous inlet pressure | 200 mbar |
Motor power 1-ph | 280 W |
Power connector 1-ph | IEC EN60320 C13 |
Recommended fuse | 10A, 250Vac rms |
Weight | 25.8 kg / 57 lb |
Inlet flange | NW25 |
Exhaust flange | NW25 |
Noise level | 52 dB(A) |
Vibration at inlet flange | < 4.5 mms-1 (rms) |
Leak tightness (static) | < 1x10-6 mbar ls-1 |
Operating temperature range | 10 to 40 °C / 41 to 104 °F |
- General clean pumping applications
- Scanning Electron Microscopes - SEM
- Beam lines and high energy physics
- Backing turbo pumps
- Centrifuges, ultra-high speed
- Coating
- Cryogenics
- Degassing/curing - oil, epoxy resin
- Distillation/extraction/filtration
- Freeze drying
- Furnaces
- Gel drying
- Laboratory bench top vacuum
- Lasers, gas recovery and recirculation
- Leak detectors, Helium
- Load locks and transfer chambers
- Rare gas recirculation
- Rare gas recovery
- Refrigeration manufacture
- Research and development
- Rotary, centrifugal evaporators
- SEM/FIB (ion beam repair)
- Solvent recovery
- Surface science instruments.
Edwards Vacuum nXDS10iC Dry Chemistry and Vapor Pump Scroll Pump 100 - 127 V, 200 - 240 V, 1ph 50/60 Hz A73602983
The nXDS version offer increased pumping speeds combined with lower ultimate pressures, lower power consumption and lower noise. Gast ballast allows for pumping of condensable vapours including water, solvents, dilute acids and bases. nXDS pumps give longer life between tip seal changes.
The nXDS-C pump is a modified version of the nXDS that is suitable for use on vapour handling processes, and may be used for some pumping applications involving corrosive substances. The nXDS-C variants have Chemraz® internal valves and stainless steel fittings for extra protection from the pumped media.
Features and Benefits
- Quiet Operation
- Intelligent and easy to use controls
- Hermetically sealed for a lubricant-free vacuum environment
- No oil to dispose of
- Long service interval
Applications
- General clean pumping applications
- Scanning Electron Microscopes - SEM
- Beam lines and high energy physics
- Backing turbo pumps
- Centrifuges, ultra- high speed
Nominal rotational speed | 1800 rpm |
Displacement | 12.7 m3h-1 / 7.5 ft3min-1 |
Peak pumping speed | 11.4 m3h-1 / 6.7 ft3min-1 |
Ultimate vacuum (total pressure) | 0.007 mbar / 0.005 Torr |
Minimum standby rotational speed | 1200 rpm |
Speed control resolution (percentage of full rotation speed) | 1% |
Pumping speed at minimum rotational speed | 7.5 |
Maximum continuous inlet pressure | 200 mbar |
Motor power 1-ph | 280 W |
Power connector 1-ph | IEC EN60320 C13 |
Recommended fuse | 10A, 250Vac rms |
Weight | 25.8 kg / 57 lb |
Inlet flange | NW25 |
Exhaust flange | NW25 |
Noise level | 52 dB(A) |
Vibration at inlet flange | < 4.5 mms-1 (rms) |
Leak tightness (static) | < 1x10-6 mbar ls-1 |
Operating temperature range | 10 to 40 °C / 41 to 104 °F |
- General clean pumping applications
- Scanning Electron Microscopes - SEM
- Beam lines and high energy physics
- Backing turbo pumps
- Centrifuges, ultra-high speed
- Coating
- Cryogenics
- Degassing/curing - oil, epoxy resin
- Distillation/extraction/filtration
- Freeze drying
- Furnaces
- Gel drying
- Laboratory bench top vacuum
- Lasers, gas recovery and recirculation
- Leak detectors, Helium
- Load locks and transfer chambers
- Rare gas recirculation
- Rare gas recovery
- Refrigeration manufacture
- Research and development
- Rotary, centrifugal evaporators
- SEM/FIB (ion beam repair)
- Solvent recovery
- Surface science instruments.